It is operated by the pilot and does not require auxiliary power such as from compressed air or electricity. Compared to the direct impingement type, it has a larger capacity. The range of pressure adjustment is wide and adjustments can be made easily. With the built-in "pressure relief valve filter" with a practical design patent No.13137, errors caused by the scale or impurities inside the pipes are prevented. Compatible with disks/ sheets. Leakage: Less than 0.05% of the standard flow
Model | FORMAT | APPLICABLE LIQUIDS |
CORRECT TEMPERATURE TO BE APPLIED ¡ÆC | CORRECT PRESSURE TO BE APPLIED MPA (KGF/CM©÷) |
MAXIMUM PRESSURE REDUCTION RATE |
MINIMUM DIFFERENCE IN PRESSURE MPA (KGF/CM©÷) |
HOW TO CONNECT THE PRODUCT |
MATERIAL | ||
PRIMARY SIDE | SECONDARY SIDE |
MAIN BODY | KEY PART | |||||||
JRV-SF11 | Pilot type | Steam | Max. 220 | Lower than 1.0 (10.0) |
0.035~0.8 (0.35~8.0) |
10:1 | 0.07(0.7) | JIS B 2239 10K FF Flanged | Cast Iron | Stainless Steel |
JRV-SF16 | 20:1 | JIS B 2239 10K RF Flanged | Dcutile Cast Iron |