Á¶±¤¾ÆÀÌ¿¤¾ÆÀÌ
Pressure Reducing Valve
JRV-SF21
(Pilot Operating Type)


As it is a pilot type, it does not require an auxiliary power source such as compressed air or electricity and has a larger capacity compared to the direct impingement type. There is a wide range of pressure adjustment available. With the built-in "pressure relief valve filter" with a practical design patent No.13137, errors caused by the scale or impurities inside the pipes are prevented. Compatible with disks/ sheets. Leakage: Less than 0.05% of the standard flow

Product specification
Model FORMAT APPLICABLE
LIQUIDS
CORRECT
TEMPERATURE
TO BE
APPLIED
CORRECT
PRESSURE
TO BE
APPLIED MPA(KGF/CM©÷)
MAXIMUM
PRESSURE
REDUCTION
RATE
MINIUM
DIFFERENCE
IN PRESSURE
MPA
(KGF/CM©÷)
HOW TO
CONNECT
THE PRODUCT
MATERIAL
Primary side Secondary
side
Main body Key part
JRV-SF21 Pilot type Steam Max.300 2.0 Lower
than 20 (20.0)
0.035~1.6
(0.35~16.0)
10:1 0.07(0.7) JIS B 2220 10K,20K
RF Ranged
Cast Steel Stainless Steel
¡ØMake adjustments so that the pressure on the secondary side is 80% or lower than the primary side pressure.
Á¶±¤¾ÆÀÌ¿¤¾ÆÀÌ