As it is a pilot type, it does not require an auxiliary power source such as compressed air or electricity and has a larger capacity compared to the direct impingement type. There is a wide range of pressure adjustment available. With the built-in "pressure relief valve filter" with a practical design patent No.13137, errors caused by the scale or impurities inside the pipes are prevented. Compatible with disks/ sheets. Leakage: Less than 0.05% of the standard flow
Model | FORMAT | APPLICABLE LIQUIDS |
CORRECT TEMPERATURE TO BE APPLIED |
CORRECT PRESSURE TO BE APPLIED MPA(KGF/CM©÷) |
MAXIMUM PRESSURE REDUCTION RATE |
MINIUM DIFFERENCE IN PRESSURE MPA (KGF/CM©÷) |
HOW TO CONNECT THE PRODUCT |
MATERIAL | ||
Primary side | Secondary side |
Main body | Key part | |||||||
JRV-SF21 | Pilot type | Steam | Max.300 | 2.0 Lower than 20 (20.0) |
0.035~1.6 (0.35~16.0) |
10:1 | 0.07(0.7) | JIS B 2220 10K,20K RF Ranged |
Cast Steel | Stainless Steel |